Length =O-Ring to O-Ring: 48
O-Ring: 14.5 mm Viton
These lack filters so extenders with filters are highly recommended!
Dead time at 14 volts @ 3 bar is approx. 0.45ms (Extremely low for such large injectors!)
Dead times at At 3 bar pressure diff:
8V 1.63ms
10V 1.13ms
12V 0.74ms
14V 0.43ms
16V 0.26ms
Static flow at 3 bar = 2200 cc/min = 210 lb/h
Static flow at 5 bar = 2865 cc/min = 273 lb/h
Static flow at 7 bar = 3350 cc/min = 320 lb/h
ATTENTION! injectors must never be Only in oxygen. If they have been driven with E85, they must be flushed with Gasoline or some form of creep oil!
There is of course no guarantee whatsoever on Injectors that have been Only, or that have gotten dirt in them.